| AT930 Pedestrian Radiation Monitor | |
| Scintillation detector | Plastic 1000x100x50 mm | 
| Energy range | 60 keV – 3 MeV | 
| Detection threshold for unshielded source at 1 m height under natural radiation background conditions not more than 0.1 µSv/h (Distance to source 1 m, source travel speed 5 km/h, probability of source detection 80 % under confidence level Р=0.95)  | 
530 kBq (241Am) 70 kBq (137Cs) 35 kBq (60Co) 180 kBq (99mTc) 75 kBq (133Ba) 50 kBq (131I)  | 
| Minimum detectable amount of radioactive materials at 1 m height under natural radiation background conditions not more than 0.1 µSv/h (Distance to source 1 m, source travel speed 5 km/h, probability of source detection 95% under confidence level Р=0.95)  | 
15 g (235U) 1.2 g (239Pu)  | 
| Typical sensitivity to gamma radiation | cps/(µSv·h-1) 60000 (241Am) 31000 (137Cs) 16500 (60Co)  | 
| False alarm rate | ≤1 per 1000 passings | 
| PC interface | RS485 | 
| Protection class | IP54 | 
| Overall dimensions | 1610x450x300 mm when anchored to the floor (An additional base of 930×760 mm size is included into the delivery set for operation without anchoring) | 
| Weight | 70 kg (83 kg with additional base)  | 