Specification
| Monitor configuration | Gamma channel: 1 x BDRM-05 Neutron channel: 2 x BDKN-05  | 
| Total number of monitors in the system | Up to 8 | 
| Time of continuous operation | ~20 h | 
| Monitors power supply | Built-in rechargeable battery pack | 
| Protection class | IР55 | 
| Dimensions and weight of monitor attached to frame (in operating position) | 2090x1025x955 mm, 78 kg | 
| Gamma radiation detection units | BDRM-05 | 
| Scintillation detector | Plastic, 1000х100х50 mm | 
| Energy range | 50 keV – 3 MeV | 
| Typical sensitivity to source radiation, cps/(µSv·h-1) | 60000 [241Am]
 32000 [137Cs] 17000 [60Co]  | 
| Neutron radiation detection units | BDKN-05 | 
| Detector | Two He-3 proportional counters in polyethylene moderator | 
| Energy range | 0.025 eV – 14 MeV | 
| Typical sensitivity to source radiation at the distance of 1 m, cps/(neutron·s-1·cm-2) | 20 [252Cf] | 
| Detection threshold for unshielded source under natural radiation background conditions not more than 0.1 µSv/h (Probability of source detection 80% under confidence level Р=0.95)  | 
||||
| Road vehicles. Travel speed 8 km/h | ||||
| Monitors configuration (location and number) | Gamma channel | Neutron channel | ||
| Detection | Categorization | |||
| Control zone
 width – 3 m, height – 2 m  | 
![]()  | 
940 kBq [241Am]
 130 kBq [137Cs] 70 kBq [60Co]  | 
1100 kBq [241Am]
 310 kBq [137Cs] 330 kBq [60Co]  | 
2.1∙104 neutron/s [252Cf] | 
![]()  | 
690 kBq [241Am]
 100 kBq [137Cs] 50 kBq [60Co]  | 
800 kBq [241Am]
 240 kBq [137Cs] 250 kBq [60Co]  | 
1.2∙104 neutron/s [252Cf] | |
| Control zone
 width – 6 m, height – 4.5 m  | 
![]()  | 
2140 kBq [241Am]
 290 kBq [137Cs] 150 kBq [60Co]  | 
2500 kBq [241Am]
 690 kBq [137Cs] 710 kBq [60Co]  | 
2.2∙104 neutron/s [252Cf] | 
![]()  | 
1570 kBq [241Am]
 210 kBq [137Cs] 110 kBq [60Co]  | 
1900 kBq [241Am]
 500 kBq [137Cs] 520 kBq [60Co]  | 
1.4∙104 neutron/s [252Cf] | |