AT2331 Emergency Alarm Dosimeter
	Detection of self-sustaining chain reaction and generation of alarm signals to evacuate personnel from hazardous area.
AT2331 can be combined with AT2327 Alarm Dosimeter and a personal computer running “SARK.NET” software to create an alarm system for detection of occurrence of self-sustaining chain reaction.
 
- Detection of self-sustaining chain reaction in full range of its characteristics
 
- High reliability
 
- Self-monitoring of component parts
 
- Backup power source
 
- Logging measurement results into non-volatile memory of alarm dosimeter
 
- Integration into external security systems
 
 
 
Request a quote
Out of stock
	 
	 
	
		
					
				
Specification
 | 
AT2331 Emergency Alarm Dosimeter | 
| Scintillation detector | 
Plastic Ø10×5 mm | 
| Minimum duration of the registered self-sustaining chain reaction | 
1 ms | 
| Measurement range of absorbed dose rate | 
0.1 µGy/h – 1 Gy/h | 
| Measurement range of absorbed dose | 
0.05 µGy – 10 Gy | 
| Energy range | 
60 keV – 3 MeV | 
| Energy dependence relative to 662 keV (137Cs) | 
±35% | 
| Selectable dose rate threshold range | 
1 µGy/h – 1 Gy/h | 
| Time interval from the moment of response to the moment when the rated alarm sound level is reached | 
≤0.5 s | 
| Alarm sound level at 1-meter distance | 
100 dB | 
| Number of measurement channels | 
Up to 32 | 
| Continuous battery operation time | 
≥6 h | 
			 
		
			 
Design and specifications are subject to change without notice.